Schneider Electric U.motion Builder...CVE-2018-7787 CVE-2018-7786 CVE-2018-7785 CVE-2018-7784
-AVACAUCIA
发布:2025-04-13
修订:2025-04-13
# ICS Advisory (ICSA-18-163-01) ## Schneider Electric U.motion Builder Original release date: June 12, 2018 | Last revised: June 18, 2018 [Print Document](javascript:window.print\(\);) [Tweet](https://twitter.com/share?url=https%3A%2F%2Fus- cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-163-01) [Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus- cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-163-01) [Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus- cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-163-01) ### Legal Notice All information products included in [https://us-cert.gov/ics](/ics) are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the...
# ICS Advisory (ICSA-18-163-01) ## Schneider Electric U.motion Builder Original release date: June 12, 2018 | Last revised: June 18, 2018 [Print Document](javascript:window.print\(\);) [Tweet](https://twitter.com/share?url=https%3A%2F%2Fus- cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-163-01) [Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus- cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-163-01) [Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus- cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-163-01) ### Legal Notice All information products included in [https://us-cert.gov/ics](/ics) are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see [https://www.us- cert.gov/tlp/](/tlp/). * * * ## 1\. EXECUTIVE SUMMARY * **CVSS v3 10.0** * **ATTENTION:** Exploitable remotely/low skill level to exploit * **Vendor:** Schneider Electric * **Equipment:** U.motion Builder * **Vulnerabilities:** Command Injection, Cross-site Scripting, and Improper Input Validation ## 2\. RISK EVALUATION Successful exploitation of these vulnerabilities could allow remote code execution. ## 3\. TECHNICAL DETAILS ### 3.1 AFFECTED PRODUCTS The following U.motion Builder Software versions are affected: * U.motion Builder versions prior to 1.3.4 ### 3.2 VULNERABILITY OVERVIEW ### 3.2.1 [STACK-BASED BUFFER OVERFLOW CWE-121](https://cwe.mitre.org/data/definitions/121.html) An input string may be evaluated as a command by the application. An attacker could exploit this to execute code, read the stack, or cause a segmentation fault in the running application. [CVE-2018-7784](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7784) has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is [(AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H)](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). ### 3.2.2 [IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND (OS COMMAND INJECTION) CWE-78](http://cwe.mitre.org/data/definitions/78.html) A remote command injection allows authentication bypass. [CVE-2018-7785](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7785) has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is [(AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H)](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). ### 3.2.3 [IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (CROSS- SITE SCRIPTING) CWE-79](http://cwe.mitre.org/data/definitions/79.html) A cross-site scripting (XSS) vulnerability exists, which could allow injection of malicious scripts. [CVE-2018-7786](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7786) has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is [(AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N)](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). ### 3.2.4 [IMPROPER INPUT VALIDATION CWE-20](http://cwe.mitre.org/data/definitions/20.html) This vulnerability is due to improper validation of input of context parameter in HTTP GET request, which could allow the disclosure of sensitive information. [CVE-2018-7787](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7787) has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is [(AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N)](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). ### 3.3 BACKGROUND * **Critical Infrastructure Sectors:** Commercial Facilities, Critical Manufacturing, and Energy * **Countries/Areas Deployed:** United States, Europe, and Asia * **Company Headquarters Location:** Paris, France ### 3.4 RESEARCHER Wei Gao of Keysight and bigric3@360A-TEAM reported these vulnerabilities to NCCIC. ## 4\. MITIGATIONS Schneider Electric has released firmware update Version 1.3.4, which includes fixes for these vulnerabilities. It is highly recommended that U.motion Builder users apply the patch in a timely manner. The firmware is available for download at: <https://www.schneider- electric.com/en/download/document/Umotion_Server_update/> Schneider Electric's security notice SEVD-2018-151-01 is available at the following location: <https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/> NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: * Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](/ics/alerts/ICS-ALERT-10-301-01). * Locate control system networks and remote devices behind firewalls, and isolate them from the business network. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. NCCIC also provides a section for [control systems security recommended practices](/ics/content/recommended-practices) on the ICS-CERT web page. Several recommended practices are available for reading and download, including [Improving Industrial Control Systems Cybersecurity with Defense-in- Depth Strategies](/sites/default/files/recommended_practices/NCCIC_ICS- CERT_Defense_in_Depth_2016_S508C.pdf). Additional mitigation guidance and recommended practices are publicly available on the [ICS-CERT website](/ics/) in the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies](/ics/tips/ICS-TIP-12-146-01B). Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities.